Alerts
An alert is one signal that something is wrong with one monitor:- A probed monitor fires an alert when at least half of its regions report the target down.
- A heartbeat fires an alert when a ping is missed, a failure is reported or the job runs too long.
Incidents
Alerts are grouped into incidents, the unit your team responds to. Each incident has a number that is unique in the workspace (#1, #2…), a severity (Critical, Major or Minor) and a timeline.
- When an alert fires and the workspace has no open incident, a new incident opens.
- While an incident is open, new alerts from any monitor in the workspace join it instead of opening another incident. Twenty monitors failing at once give you one incident, not twenty.
- When every alert of an incident recovers, the incident resolves automatically.
Statuses
Respond to an incident
From Incidents, open an incident to see its alerts, the affected monitors and a timeline of what happened and who did it (a person, an API key, an MCP client or the system). Then:- Acknowledge it to show you are on it, from the incident or straight from the list. You become its assignee and the reminders stop for everyone. Only members of the workspace can acknowledge.
- Resolve it to close it together with its firing alerts. If a monitor fails again afterwards, a new incident opens.
- Mark as duplicate to close it and label it as a duplicate in your history.
POST /incidents/{incident_id}/acknowledge, /resolve, /duplicate, and PATCH /incidents/{incident_id} for the severity and assignee) and from MCP (acknowledge_incident). Acknowledging an incident that is already acknowledged or resolved fails with 409 conflict.
Acknowledge from an alert
Incident emails, Discord messages and webhook payloads include an Acknowledge link. It opens the incident in the app: sign in if needed (you come back to the incident afterwards), then confirm. If the incident belongs to another of your workspaces, the app switches to that workspace first. Opening the link never acknowledges anything by itself, so email security scanners that follow links can’t acknowledge for you.Reminders
While nobody has acknowledged an incident, the channels that were told about it are reminded every 10 minutes, up to 4 times. Reminders stop as soon as someone acknowledges or resolves the incident. Incidents whose alerts are all degraded (slow, not down), or whose firing monitors are all in a maintenance window, are not reminded. Reminders, grouping and acknowledging are available on every plan.Escalation
To notify more people when nobody responds (for example every member after 5 minutes), give the monitor or the workspace an escalation policy. Acknowledging or resolving the incident stops it.An incident that resolved automatically reopens if one of its heartbeat alerts fails again within the heartbeat’s flap window. An incident a person resolved or marked as a duplicate never reopens; a new failure opens a new incident.
Notifications
Incidents notify the notification channels of their monitors, according to the events each channel receives:- The first notification of an incident goes out at once, listing every monitor involved.
- Monitors that join in the following minute are grouped into one update, and later updates go out at most once a minute. Twenty monitors failing together give each channel one message, then one update, not twenty.
- Reminders follow while nobody acknowledges it, then one message when it resolves.
incident.opened, incident.updated, incident.reminder and incident.resolved, plus incident.acknowledged, incident.escalated and the per-monitor monitor.* events. See Webhooks.
Alerts that fire during a maintenance window for the affected monitors are recorded but not notified.